The S-Line from Gorman-Rupp is a premium range of diesel-driven, sound-attenuated pump sets built for applications where performance, reliability, and quiet operation go hand in hand. These pump sets include self-priming and priming assisted pump technology with powerful diesel engines offering efficient performance in both urban and remote environments.
The S-Line series pump sets are equipped with Stage V certified diesel engines and a compact, fully or partially enclosed canopy. They are engineered to operate quietly in tough conditions- without the need for AdBlue. Whether you’re managing stormwater, handling wastewater bypass, drilling fluids or responding to emergencies, the S-Line offers a reliable and reduced noise solution that is ready to go.
S-Line pump sets come in multiple configurations- both self-priming and priming-assisted- with a large integrated fuel tank and rugged steel frame. They’re ready for continuous operation, easy to transport, and fast to deploy.
The Gorman-Rupp S-Line VPA3-70-LS is a diesel-powered priming-assisted centrifugal pump set for pumping clean, dirty and sewage water.
The Gorman-Rupp S-Line PA4-160-L/LS is a diesel-powered priming assisted centrifugal pump set for pumping clean and dirty water (L version) and/or sewage (LS version).
The Gorman-Rupp S-Line PA4-160-L/LS is a diesel-powered priming assisted centrifugal pump set for pumping clean and dirty water (L version) and/or sewage (LS version).
The Gorman-Rupp S-Line PAV4-200 is the definitive answer for heavy-duty pump applications. These dry self-priming Vortex centrifugal pumps are specially designed for heavy-duty work. Think of pumping bentonite when performing horizontal directional drilling, or pumping sewage water during temporary diversions.
The Gorman-Rupp S-Line PAV4-220 Performance+ is the definite answer for heavy duty pumping applications. These dry self-priming Vortex centrifugal pumps from Gorman-Rupp are designed for heavy duty applications and offer higher pressure compared to the standard model. Typical applications are pumping drilling fluid in HDD operation, or pumping sewage water during temporary bypass operations.
The Gorman-Rupp S-Line PA6-440-L/LS is a diesel powered priming-assisted centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line PA6-440-L/LS is a diesel powered priming-assisted centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line PA6-550-L/LS is a diesel driven priming-assisted centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line PA6-550-L/LS is a diesel driven priming-assisted centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line PAV6-450 is the definite answer for heavy duty pumping applications. These dry self-priming Vortex centrifugal pumps from Gorman-Rupp are designed for heavy duty applications such as pumping drilling fluid in HDD drilling, or pumping sewage water during temporary bypass operations.
The Gorman-Rupp S-Line PAV6-490 Performance+ is the definite answer for heavy duty pumping applications. These dry self-priming Vortex centrifugal pumps from GormanRupp are designed for heavy duty applications and offer higher pressure compared to the standard model. Typical applications are pumping drilling fluid in HDD operation, or pumping sewage water during temporary bypass operations.
The Gorman-Rupp S-Line 82-45 is a diesel-powered wet self-priming pump set for pumping clean and dirty water and for light or non-frequent use of abrasive fluids.
The Gorman-Rupp S-Line T2 is a diesel-powered self-priming centrifugal pump set for pumping clean, dirty and sewage water.
The Gorman-Rupp S-Line 83-90 is a diesel-powered self-priming pump set for pumping clean and dirty water and for light or non-frequent use of abrasive fluids.
The Gorman-Rupp S-Line T3 is a diesel-powered self-priming centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line T3 is a diesel-powered self-priming centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line U3-85-L is a diesel-powered self-priming centrifugal pump set for pumping clean and slightly contaminated water.
The Gorman-Rupp S-Line T4-160-L/LS is a diesel-powered self-priming centrifugal pump set for pumping clean and dirty water (L version) and/or sewage (LS version).
The Gorman-Rupp S-Line T4-160-L/LS is a diesel-powered self-priming centrifugal pump set for pumping clean and dirty water (L version) and/or sewage (LS version).
The Gorman-Rupp S-Line U4-140-L is a diesel-powered self-priming centrifugal pump set for pumping clean and slightly contaminated water.
The Gorman-Rupp S-Line T6-280-L/LS is a diesel powered self-priming centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
The Gorman-Rupp S-Line T6-280-L/LS is a diesel powered self-priming centrifugal pump set for pumping clean and dirty water (L-version) and/or sewage (LS-version).
Gorman-Rupp’s S-Line is a range of diesel driven pump sets specially built for applications where quiet operation, high reliability and strong performance are key. These pump sets are suitable for both urban and remote areas and combine advanced self-priming or dry self-priming technology with powerful Stage V diesel engines – without requiring AdBlue.
The S-Line units feature a large integrated fuel tank and a rugged steel frame, making them ideal for continuous use, easy transport and fast deployment.
Wet self-priming pumps require the pump casing to be initially filled with liquid before starting. These pumps have two chambers: a vacuum chamber and a pressure chamber, connected by a recirculation port. Once running, the pump uses circulating water in the chamber to evacuate air from the suction line. Heavier water is recirculated back through the recirculation port, while lighter air escapes through the discharge. This method ensures efficient operation and reliable performance in various pumping applications.
Dry self-priming pumps (also called prime-assisted pumps) don’t require pre-filling. They can start even when the system, including the pump casing, is empty. These centrifugal pumps feature an additional priming assist device, typically an air vacuum diaphragm pump or a compressor/venturi system. When the pump starts, the vacuum pump creates a vacuum in the suction line. Then, atmospheric pressure pushes the liquid into the suction line and starts priming the pump. This technology ensures reliable performance and ease of use, making it ideal for various industrial applications.
Stage V engines represent a remarkable fusion of power, efficiency, and environmental responsibility. Their ability to meet strict emissions standards while delivering impressive performance makes them a reliable choice today. These are some advantages making Gorman-Rupp S-Line pumpsets equipped with Stage V engines preferred choice:
S-Line diesel driven pump sets may have up to 750 m3/h capacity (flow) and 64 m maximum head depending of the model.
S-Line pump sets are engineered for continuous operation but they do not have a fixed run time because run time varies significantly based on the engine size, load, fuel tank capacity and the specific application they used in. The Gorman-Rupp S-Line diesel pump sets designed with different fuel tank capacities between 60 and 250 liters depending on the models and sizes.
S-Line key features for continuous operation include:
Maintenance costs vary significantly by application and pump model. The Gorman-Rupp S-Line pump sets are designed for maximum performance with minimal maintenance and our experienced team is always ready to help you for your maintenance requests. You can reach us from +31 (0)6-3033 5189 after business hours also for your urgent needs.
S-Line maintenance advantages:
Yes, modern S-Line diesel pumps are compatible with HVO (Hydrotreated Vegetable Oil). Using HVO with Stage V engines reduces CO2 emissions, making it a powerful tool for meeting environmental sustainability goals and reducing carbon footprints.
HVO (Hydrotreated Vegetable Oil) advantages:
There is no general noise standard for “pumps” but rather a directive for specific types of equipment. Noise regulations for these equipment’s in urban areas depend on the specific country or region, but generally, limits vary by location type (residential, commercial, industrial) and time of day (day vs. night).
The Gorman-Rupp S-Line diesel-driven mobile pump sets are equipped with a compact, fully or partially enclosed sound insulated canopy to keep noise levels low for populated or sound sensitive areas. S-Line pump sets sound measured max. 82 dB, at 1 meter distance and 1 meter height.
S-Line acoustic benefits:
Need help selecting the best solution? Our pump experts are here to help you. Feel free to contact us for tailored recommendations.
Email: GREsales@gormanrupp.com
Phone: +31 (0)85 7730080
Leave your name and email address below and receive the brochure directly in your inbox.
Laat uw naam en e-mailadres achter en u ontvangt de brochure direct in uw inbox.
Leave your name and email address below and receive the brochure directly in your inbox.